What is an Air Change Per Hour in Construction in the USA?

Understanding Air Change Per Hour (ACH) in Construction

In construction projects across the USA, ensuring proper ventilation and air circulation is crucial for maintaining indoor air quality (IAQ), energy efficiency, and occupant comfort. One of the most important metrics used to evaluate ventilation performance is Air Changes Per Hour (ACH). This parameter measures how frequently the air within a room or building is replaced with fresh air within an hour, either through natural or mechanical ventilation systems.

How is Air Change Per Hour (ACH) Calculated?

The formula for calculating ACH is: ACH=(CFM×60RoomVolume)ACH = \left( \frac{CFM \times 60}{Room Volume} \right)

Where:

  • CFM (Cubic Feet per Minute) refers to the airflow rate provided by the HVAC system.
  • Room Volume is the total cubic feet of space in the given area.
  • 60 represents the minutes in an hour to convert the CFM to an hourly rate.

For example, if an HVAC system supplies 500 CFM to a 10,000 cubic feet room, the ACH would be: ACH=(500×6010,000)=3ACH = \left( \frac{500 \times 60}{10,000} \right) = 3

This means the air in the room is completely replaced three times per hour.

Why is ACH Important in Construction?

1. Ensuring Indoor Air Quality (IAQ)

Proper air exchange is vital in residential, commercial, and industrial buildings to remove pollutants such as:

  • Carbon dioxide (COâ‚‚)
  • Volatile organic compounds (VOCs)
  • Dust, allergens, and airborne pathogens
  • Radon and other harmful gases

High ACH values help mitigate stale air accumulation and improve health and safety conditions in enclosed spaces.

2. Compliance with USA Building Codes

Construction projects must adhere to ASHRAE 62.1 & 62.2 standards, which set minimum ventilation rates based on occupancy type and space function. Common guidelines include:

  • Offices & Retail Spaces: 6-8 ACH
  • Hospitals & Healthcare Facilities: 12-15 ACH
  • Laboratories & Clean Rooms: 20+ ACH

These values ensure that buildings comply with OSHA and EPA air quality regulations, enhancing sustainability and occupant comfort.

3. Energy Efficiency Considerations

While high ACH values improve air circulation, excessive air changes can lead to increased heating and cooling loads. Modern HVAC systems use:

  • Energy recovery ventilators (ERVs)
  • Demand-controlled ventilation (DCV)
  • Smart sensors and automated air exchange systems

These technologies balance air quality with energy efficiency, reducing operational costs while maintaining regulatory compliance.

Air Change Per Hour Requirements in Different Building Types

1. Residential Buildings

Most homes in the USA rely on natural ventilation, with typical ACH values between 0.5 and 1.5. Tighter homes with modern insulation may require mechanical ventilation systems to meet ASHRAE standards.

2. Commercial Buildings

Retail stores, office buildings, and shopping malls require 6-8 ACH, depending on occupancy density and HVAC system capabilities.

3. Industrial and Manufacturing Facilities

Factories, workshops, and warehouses require higher ACH levels (10-15 ACH) to remove fumes, dust, and chemical vapors generated by manufacturing processes.

4. Healthcare and Laboratory Spaces

Hospitals and clean rooms demand strict air exchange controls to prevent airborne contamination.

  • Surgical rooms: 15-20 ACH
  • Isolation rooms: 12+ ACH with negative pressure
  • Laboratories: 6-12 ACH, based on chemical exposure risk

How to Optimize ACH in Construction Projects

1. Conducting an Airflow Analysis

Before finalizing an HVAC design, contractors should:

  • Measure current airflow rates using anemometers and airflow sensors.
  • Calculate ACH for different zones within the building.
  • Ensure compliance with ASHRAE and local codes.

2. Implementing Efficient Ventilation Strategies

  • Use demand-controlled ventilation (DCV) systems to adjust airflow based on occupancy.
  • Install high-efficiency particulate air (HEPA) filters to maintain clean indoor air.
  • Incorporate natural ventilation solutions, such as operable windows and atriums, in climate-appropriate regions.

3. Balancing ACH with HVAC Efficiency

Excessive ACH rates can strain heating and cooling systems. To optimize performance:

  • Use energy recovery ventilators (ERVs) to retain heat/cooling energy.
  • Install variable air volume (VAV) systems to regulate airflow dynamically.
  • Conduct regular HVAC maintenance to prevent efficiency losses.

Conclusion

Understanding Air Changes Per Hour (ACH) is essential for designing safe, efficient, and regulation-compliant buildings in the USA construction industry. By implementing optimal air exchange strategies, contractors can enhance indoor air quality, reduce energy costs, and ensure occupant comfort.